Are Baby Monitors Accurate? What a Hospital Test of Two Wearables Found
Moderate evidence Evidence review
Citation record (Scite): Cited by 56 publications. Of 44 citation statements checked, 0 supporting, 0 contrasting, 40 mentioning.
Published: ยท Last updated:
โ General information only โ this page explains one study and isn't medical or parenting advice for your specific child.
TL;DR: Parents asking whether baby monitors are accurate usually want to know whether the numbers on the app can be trusted. The one study that checked wearable monitors against a hospital machine, Bonafide and colleagues in JAMA in 2018, got two opposite answers from the only two devices of their kind. The Owlet Smart Sock 2 flagged most of the low-oxygen readings the hospital monitor recorded, with a sensitivity of 88.8%, and it also produced false alarms. The Baby Vida flagged none of them, a sensitivity of 0.0%, and produced no false alarms on oxygen at all. The babies were hospital patients aged 0 to 6 months, watched for 60 minutes at a time, and the study measured readings only. It says nothing about sleep tracking, temperature sensors, today's models, or whether a monitor prevents harm.
The short answer: are baby heart monitors accurate, on this evidence?
It depends which monitor, and the difference is not small. In this test, one wearable baby monitor caught most of the low-oxygen readings and sometimes cried wolf, while the other missed every low-oxygen reading the reference monitor recorded during the hours studied. Both results come from the same small hospital test, so neither should be turned into a verdict on every device sold since. What the study does establish is that accuracy is a property of a specific device, not of the product category. A parent cannot assume that because a monitor reports oxygen saturation and pulse rate, it reports them correctly.
What did the researchers actually test?
The study ran at the Children's Hospital of Philadelphia from July through December 2017, in the general pediatrics and cardiology wards. The infants were aged 0 to 6 months. Each baby wore the reference monitor, an FDA-cleared Masimo Radical-7 set to 16-second averaging, on one foot, and a consumer monitor on the other foot. The consumer monitor went on in a random sequence for 60 minutes while the infant was asleep or awake and calm.
The two consumer devices were the only two smartphone-integrated baby monitors using pulse oximetry that were marketed at the time: the Owlet Smart Sock 2, called consumer monitor A in the letter, and the Baby Vida, consumer monitor B. The letter notes that monitors of this kind were popular with parents and were not regulated by the US Food and Drug Administration. Low oxygen, called hypoxemia, was defined as an oxygen saturation under 91%, and a slow pulse, bradycardia, as a pulse rate under 90 beats per minute. To keep the comparison fair, the researchers randomly selected up to 10 stable paired readings per baby for the analysis.
What was the Owlet baby monitor accuracy for oxygen?
For the Owlet Smart Sock 2, the oxygen analysis covered 262 randomly selected readings from 28 babies, and 30.5% of those readings were low-oxygen readings on the reference monitor. The Owlet's sensitivity was 88.8%, with a 95% confidence interval from 79.4% to 98.1%, which means it flagged most of the readings the hospital monitor called low. Its specificity was 85.7%, from 72.6% to 98.8%, so most normal readings were also reported as normal, though not all of them.
The Baby Vida's oxygen analysis covered 300 readings from 30 babies, with a low-oxygen share of 34.0%. Its sensitivity was 0.0%, with a 97.5% confidence interval from 0.0% to 3.6%. Its specificity was 100.0%, from 98.2% to 100.0%. Put together, the Baby Vida never reported a low-oxygen reading during the study, which is why it also never raised a false one.
Does the Owlet give false alarms, and what got missed?
In counts rather than percentages, the Owlet recorded 71 true-positive low-oxygen readings in 12 babies, so it did catch real events. It missed 9 low-oxygen readings in 5 babies. It also produced 26 false-positive readings in 6 babies, readings where it reported low oxygen that the reference monitor did not show, alongside 156 true-negative readings in 19 babies. A false alarm usually means a frightened parent checking a sleeping baby who turns out to be fine, and the more sensitive device produced some of those here.
The Baby Vida's counts run the other way. It recorded no true-positive low-oxygen readings at all. It missed 102 low-oxygen readings in 14 babies, while recording 198 true-negative readings in 21 babies and no false positives on oxygen. A monitor that stays silent can feel reassuring, and in this study the silent monitor was silent through every low-oxygen reading the hospital machine recorded.
What about the pulse rate readings?
Here the study can say much less, because slow pulse rates barely occurred in these babies. For the Owlet, the pulse analysis covered 235 readings from 28 babies, and only 0.8% of them were bradycardia readings on the reference monitor. Its sensitivity for bradycardia was 0.0%, but the 97.5% confidence interval runs from 0.0% to 84.2%, which is too wide to settle anything. Its specificity was 100.0%, from 98.4% to 100.0%.
For the Baby Vida, the pulse analysis covered 294 readings from 30 babies, with a bradycardia share of 0.3%. Its sensitivity was also 0.0%, with an interval from 0.0% to 97.5%, and its specificity was 82.3%, from 72.5% to 92.0%. With almost no slow-pulse events in the sample, neither device got a meaningful test on that measure, and this part of the study is inconclusive.
What this research can't tell you
It did not measure sleep. There are no sleep stages, sleep durations or night-waking figures anywhere in this letter, and no comparison against polysomnography or actigraphy. It tested oxygen saturation and pulse rate only, so it cannot grade a sleep tracker. Camera-based and radar-based trackers were not tested either.
It did not test temperature readings. A large share of parents asking are baby monitors accurate mean the room-temperature number on a camera monitor. This study is silent on that. The devices here read oxygen and pulse from the baby's foot, and nothing in the letter rates a temperature sensor.
The babies were hospital patients, watched for an hour. Participants were infants aged 0 to 6 months in hospital wards, observed for 60 minutes while asleep or awake and calm. Babies born before 34 weeks' gestation were excluded, as were babies who were critically ill, anaemic with hemoglobin under 10 g/dL, febrile at 38.0 ยฐC or above, hypothermic under 36.0 ยฐC, hypotensive, or with compromised perfusion. None of this is the same as a healthy baby monitored at home through the night.
The devices are 2017 models. The Owlet Smart Sock 2 and the Baby Vida were tested as sold at the time. The results do not transfer to current monitor models, and they should not be quoted as a rating of anything a parent can buy today. A baby breathing monitor sock, a breathing mat or a camera from a current range needs its own test, and this letter is not one.
It cannot say a monitor prevents harm, or calms parents. The study did not test whether using a monitor changes parent behaviour, parent anxiety, parent sleep or baby sleep, and it did not test whether monitors prevent SIDS or any other outcome. It also used another pulse oximeter as its reference standard rather than arterial blood gas measurement, so even the accuracy figures are a comparison between two oximeters. For the sleep questions around monitors, see also when to start sleep training and is bed sharing safe.
Try this tonight
The two devices tested are no longer current models, so the figures belong to them alone, but the habit of asking for the test behind the numbers is worth keeping for whatever monitor a parent considers next.
- Ask which numbers a device actually measures before trusting any of them. This test covered oxygen saturation and pulse rate from foot-worn sensors. A camera's temperature reading and a breathing mat's movement counts are different technologies, and this study says nothing about either.
- Treat every alarm as a prompt to look at the baby. The more accurate oxygen monitor in this test still produced 26 false-positive readings, so an alarm is a reason to check, and what you find when you check is the information that matters.
- Do not read a silent monitor as proof that all is well. One device here never false-alarmed on oxygen because it never flagged a low reading at all. Silence told the parents nothing about whether the sensor was working.
- Keep ordinary safe-sleep practice in place whatever the app shows. This study measured readings, not outcomes, and it offers no evidence that any monitor prevents harm, so a monitor cannot take the place of the basics.
- If the numbers on your monitor worry you, take them to your pediatrician. A clinician who knows your baby can judge what a reading means in a way a percentage in a study of hospital patients cannot.
Frequently Asked Questions
Are baby heart monitors accurate?
For oxygen readings, the two monitors tested gave opposite answers. The Owlet Smart Sock 2 had a sensitivity of 88.8% and a specificity of 85.7% against a hospital oximeter, so it caught most low-oxygen readings and mislabelled some normal ones. The Baby Vida had a sensitivity of 0.0% and a specificity of 100.0%, catching none. For pulse rate, so few slow-pulse readings occurred in the study that neither device got a meaningful test. Both were 2017 models tested in hospital patients, so the figures describe those devices in that setting, not every heart monitor on sale now.
What is the owlet baby monitor accuracy in this study?
For the Owlet Smart Sock 2, oxygen sensitivity was 88.8% (95% CI, 79.4% to 98.1%) and specificity was 85.7% (72.6% to 98.8%), across 262 readings from 28 babies. In counts, it caught 71 true low-oxygen readings, missed 9 and false-alarmed on 26. For pulse rate, sensitivity was 0.0% with a very wide interval, 0.0% to 84.2%, because almost no slow-pulse readings occurred, and specificity was 100.0%.
Does the owlet give false alarms?
In this test, yes. The Owlet produced 26 false-positive low-oxygen readings in 6 babies, out of 262 readings analysed. Those are readings where the sock reported low oxygen and the hospital monitor on the other foot did not. The same device also caught 71 true low-oxygen readings, so the false alarms came packaged with the sensitivity that caught real events. Whether current Owlet models behave the same way is a question this 2018 letter cannot answer.
What about a baby breathing monitor sock or a breathing mat?
One of the tested devices was a sock. The Owlet Smart Sock 2 is a foot-worn sensor that sends oxygen and pulse readings to a phone, and it is the device whose oxygen sensitivity was 88.8% in this study. Breathing mats, under-mattress pads and cameras work differently and were not part of this test at all, so the letter gives no verdict on them. A parent choosing a breathing mat is outside what this evidence covers.
Do baby monitors prevent SIDS?
This study does not say, because it never looked at outcomes. It compared readings between two oximeters over 60-minute sessions in hospital and recorded nothing about SIDS, deaths, or babies' health afterwards. The letter also notes that consumer monitors of this kind were not regulated by the US Food and Drug Administration. Any claim that a monitor prevents SIDS goes beyond what this research tested.
๐ The paper at a glance
Bonafide CP, Localio AR, Ferro DF, Orenstein EW, Jamison DT, Lavanchy C, Foglia EE. (2018). Accuracy of Pulse Oximetry-Based Home Baby Monitors. JAMA, 320(7), 717โ719. https://doi.org/10.1001/jama.2018.9018
Peer-review status: Peer-reviewed journal
Practical, proven parenting steps, once a week.
Get science-backed insight delivered straight to your inbox. No spam, no guilt-tripping, no daily noise.
Disclaimer: This article explains scientific research and is not medical or parenting advice for a specific child.
Published: ยท Last updated: